Search results

Found 939 matches
NTU method - actual heat transfer rate (q) (relative to the cold fluid)

The Number of Transfer Units (NTU) Method is used to calculate the rate of heat transfer in heat exchangers (especially counter ... more

NTU method - maximum heat transfer rate (q_max)

The Number of Transfer Units (NTU) Method is used to calculate the rate of heat transfer in heat exchangers (especially counter ... more

Rayleigh number (for the mushy zone of a solidifying alloy - related to isotherm speed)

In fluid mechanics, the Rayleigh number (Ra) for a fluid is a dimensionless number associated with buoyancy-driven flow, also known as free convection or ... more

Maximum thermal efficiency of an Otto cycle

The constant volume adiabatic flame temperature is the temperature that results from a complete combustion process that occurs without any work, heat ... more

Worksheet 324

The main span of San Francisco’s Golden Gate Bridge is 1275 m long at its coldest. The bridge is exposed to temperatures ranging from –15ºC to 40ºC . (a) What is its change in length between these temperatures? Assume that the bridge is made entirely of steel.

Strategy

Use the equation for linear thermal expansion to calculate the change in length , ΔL . Use the coefficient of linear expansion, α ,for steel from Table 13.2, and note that the change in temperature, ΔT , is 55ºC

Thermal Expansion - Linear

(b) convert the change in temperature if Kelvin and Fahrenheit degrees. **
**this section is not included in the Reference material

Celsius <-> Kelvin
Celsius <-> Fahrenheit

Discussion

Although not large compared with the length of the bridge, this change in length is observable. It is generally spread over many expansion joints so that the expansion at each joint is small.

Reference : OpenStax College,College Physics. OpenStax College. 21 June 2012.
http://openstaxcollege.org/textbooks/college-physics
Creative Commons License : http://creativecommons.org/licenses/by/3.0/

Womersley Number

The Womersley number (α) is a dimensionless number in biofluid mechanics. It is a dimensionless expression of the pulsatile flow frequency in relation to ... more

Wind Chill - North American and UK - Fahrenheit scale

Wind-chill or windchill, (popularly wind chill factor) is the perceived decrease in air temperature felt by the body on exposed skin due to the flow of ... more

Wind Chill - North American and UK - Celsius scale

Wind-chill or windchill, (popularly wind chill factor) is the perceived decrease in air temperature felt by the body on exposed skin due to the flow of ... more

Maximum thermal efficiency of a Diesel cycle

The Diesel cycle is a combustion process of a reciprocating internal combustion engine. In it, fuel is ignited by heat generated by compressing air in the ... more

NTU method - heat capacity ratio