'

Search results

Found 496 matches
Root mean square of phase-to-phase voltage

In mathematics, the root mean square , also known as the quadratic mean, is a statistical measure of the magnitude of a varying quantity. In a balanced ... more

Voltage AC (3-phases)

AC 3-phases sinusoidal voltage (rms – root mean square) for a triangle waveform centered about zero, can be described mathematically as a function of peak ... more

Ripple voltage (full-wave rectifier))

The most common meaning of ripple in electrical science is the small unwanted residual periodic variation of the direct current (DC) output of a power ... more

Ripple voltage (half-wave rectifier))

The most common meaning of ripple in electrical science is the small unwanted residual periodic variation of the direct current (DC) output of a power ... more

Ripple factor (choke)

For the root mean square value of the ripple voltage, the calculation is more involved as the shape of the ripple waveform has a bearing on the result. ... more

Current (AC-rms)

The RMS current for sinusoidal systems can be described mathematically as a function of peak current.

... more

AC Power

In alternating current circuits, energy storage elements such as inductance and capacitance may result in periodic reversals of the direction of energy ... more

Ripple factor

For the root mean square value of the ripple voltage, the calculation is more involved as the shape of the ripple waveform has a bearing on the result. ... more

Voltage (AC)

Alternating current voltage can be described mathematically as a function of time, angular frequency and peak voltage

... more

Instantaneous power for L1 (Three-phase electric application)

In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating current voltages that are offset in time ... more

Instantaneous power for L2 (Three-phase electric application)

In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating current voltages that are offset in time ... more

Instantaneous power for L3 (Three-phase electric application)

In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating current voltages that are offset in time ... more

Total constant power (Three-phase electric application)

In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating current voltages that are offset in time ... more

Motor velocity constant

The constant Kv (motor velocity constant, or the back EMF constant) is a value used to describe characteristics of electrical ... more

Time-varying instantaneous voltages for L1 (Three-phase electric application)

In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating current voltages that are offset in time ... more

Total harmonic distortion

The total harmonic distortion, or THD, of a signal is a measurement of the harmonic distortion present and is defined as the ... more

Time-varying instantaneous voltages for L3 (Three-phase electric application)

In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating current voltages that are offset in time ... more

Time-varying instantaneous voltages for L2 (Three-phase electric application)

In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating current voltages that are offset in time ... more

Total constant power (Three-phase electric application)

In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating current voltages that are offset in time ... more

Instantaneous current for L1(Three-phase electric application)

In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating current voltages that are offset in time ... more

Instantaneous current for L3 (Three-phase electric application)

In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating current voltages that are offset in time ... more

Instantaneous current for L2 (Three-phase electric application)

In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating current voltages that are offset in time ... more

Miles Equation

In 1954, Miles developed his version of this equation for GRMS as he was researching fatigue failure of aircraft structural ... more

Blade root bending moment load due to yaw

The blade root bending moment due to the wind turbine yaw operation. The yaw rate can be calculated for passive yaw, or is defined by the design for active ... more

Shaft bending moment due to yaw (2-bladed rotor)

The shaft bending moment due to yaw depends on the blades of the rotor. In this case the rotor has 2 blades

... more

Root mean square speed

Root-mean-square speed is the measure of the speed of particles in a gas that is most convenient for problem solving within the kinetic theory of gases. It ... more

Sound Pressure Level

Sound pressure or acoustic pressure is the local pressure deviation from the ambient (average, or equilibrium) atmospheric pressure, caused by a sound ... more

Child's Law - related to anode voltage

First proposed by Clement D. Child in 1911, Child’s law states that the space-charge limited current (SCLC) in a ... more

Motor Torque constant

The constant K_v (motor velocity constant, or the back EMF constant) is a value used to describe characteristics of electrical ... more

Motor Torque constant - with velocity constant

The constant K_v (motor velocity constant, or the back EMF constant) is a value used to describe characteristics of electrical ... more

...can't find what you're looking for?

Create a new formula