Search results

Found 820 matches
Allowable Strength Design Load combination (eq5a)

In structural engineering, a structure is a body or combination of pieces of rigid bodies in space to form a fitness system for supporting loads. ... more

Allowable Strength Design Load combination (eq5b)

In structural engineering, a structure is a body or combination of pieces of rigid bodies in space to form a fitness system for supporting loads. ... more

Allowable Strength Design Load combination (eq2)

In structural engineering, a structure is a body or combination of pieces of rigid bodies in space to form a fitness system for supporting loads. ... more

Worksheet 324

The main span of San Francisco’s Golden Gate Bridge is 1275 m long at its coldest. The bridge is exposed to temperatures ranging from –15ºC to 40ºC . (a) What is its change in length between these temperatures? Assume that the bridge is made entirely of steel.

Strategy

Use the equation for linear thermal expansion to calculate the change in length , ΔL . Use the coefficient of linear expansion, α ,for steel from Table 13.2, and note that the change in temperature, ΔT , is 55ºC

Thermal Expansion - Linear

(b) convert the change in temperature if Kelvin and Fahrenheit degrees. **
**this section is not included in the Reference material

Celsius <-> Kelvin
Celsius <-> Fahrenheit

Discussion

Although not large compared with the length of the bridge, this change in length is observable. It is generally spread over many expansion joints so that the expansion at each joint is small.

Reference : OpenStax College,College Physics. OpenStax College. 21 June 2012.
http://openstaxcollege.org/textbooks/college-physics
Creative Commons License : http://creativecommons.org/licenses/by/3.0/

Reed's Law

Reed’s law is the assertion of David P. Reed that the utility of large networks, particularly social networks, can scale exponentially with the size ... more

Equation of exchange

Monetarists assert that the empirical study of monetary history shows that inflation has always been a monetary phenomenon. The quantity theory of money, ... more

Working f-Number (related to uncorrected f-Number)

In optics, the f-number (sometimes called focal ratio, f-ratio, f-stop, or relative aperture) of an optical system is the ratio of the lens’s focal ... more

Factor of safety

Factor of safety (FoS) or (FS), is a term describing the structural capacity of a system beyond the expected loads or actual loads. Essentially, how much ... more

Acousto-optic deflector

An acousto-optic deflector spatially controls the optical beam. In the operation of an Acoustic-optic deflector the power driving the acoustic transducer ... more

Allowable Strength Design Load combination (eq3)

In structural engineering, a structure is a body or combination of pieces of rigid bodies in space to form a fitness system for supporting loads. ... more

...can't find what you're looking for?

Create a new formula